APC Zubehör / Service Bypass PDU 230V 16A 6xC13 1xC19

Homepage APC Zubehör / Service Bypass PDU 230V 16A 6xC13 1xC19
APC Zubehör / Service Bypass PDU  230V 16A 6xC13 1xC19 (SBP3000RMI)
APC Zubehör / Service Bypass PDU  230V 16A 6xC13 1xC19 (SBP3000RMI)
APC Zubehör / Service Bypass PDU  230V 16A 6xC13 1xC19 (SBP3000RMI)
APC Zubehör / Service Bypass PDU  230V 16A 6xC13 1xC19 (SBP3000RMI)

APC Zubehör / Service Bypass PDU 230V 16A 6xC13 1xC19

SKU:
SBP3000RMI
EAN:
0731304266747
  • Type PDU
Beschrijving

APC SERVICE BYPASS PDU, 230V 16AMP W/ (6) IEC C13 AND (1) C19


APC Maintenance Bypass Panels , Input: 230V , Input Connections: IEC-320 C20 , Cord Length: 8.2 feet ( 2.5 meters ) , Output: 230V , Output Connections: IEC 320 C13,IEC 320 C19,IEC Jumpers

Output

Nominal Output Voltage: 230V
Maximum Total Current Draw per Phase: 16A
Output Connections: 6) IEC 320 C13 (1) IEC 320 C19 (1) IEC Jumpers
Always on Outlets: 7
Overload Protection: Yes
Cord Length: 1 meters

Input

Nominal Input Voltage: 230V
Input Frequency: 50/60 Hz
Input Connections: IEC-320 C20
Cord Length: 2.5 meters
Number of Power Cords: 1
Acceptable Input Voltage: 220-240 VAC
Maximum Line Current per phase: 16A
Maximum Input Current per phase: 16A
Load Capacity: 3000 VA
Load Power Factor Range: 0 to 1

Physical

Net Weight: 2.09 KG
Maximum Height: 89.00 mm
Maximum Width: 432.00 mm
Maximum Depth: 76.00 mm
Shipping Weight: 3.91 KG
Shipping Height: 151.00 mm
Shipping Width: 463.00 mm
Shipping Depth: 295.00 mm
Color: Black
Units per Pallet: 56.00

Environmental

Operating Environment: 0 - 40 °C
Operating Relative Humidity: 0 - 95%
Operating Elevation: 0-4500 meters
Storage Temperature: -15 - 45 °C
Storage Relative Humidity: 0 - 95%
Storage Elevation: 0-15000 meters

Conformance

Regulatory Approvals: VDE
Standard Warranty: 2 years repair or replace
Environmental Compliance: RoHS 7b Exemption,REACH: Contains No SVHCs

Features

Transfer rate is within the industry standard and within the time power supplies will typically drop loads. The transfer of one power source to another is seamless to the connected equipment avoiding disruption of equipment performance.

(3) Breaker maintenance bypass panel to isolate the UPS from the critical load

Please note that although care has been taken in the degree of relevancy, pictures are for display purposes only, and product appearance may differ from what you see. If there are any discrepancies between the product headline, description and picture, the correct information will be in the product headline (i.e. computer systems may not come with monitors even if pictured that way). If anything is unclear, please email support before placing your order.